that is known for its excellent performance along with longevity. The Water Heating and Cooling System bring repeated orders from the customers along with their huge appreciation. Furthermore, the Water Heating and Cooling System can be availed at pocket friendly prices.
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating Capacity | L/HR | - | 100 |
Water Cooling Capacity | L/HR | 100 | - |
Power in put (per hour) | Kw | 1.25 | - |
No. of units | No | 1 | - |
Total Cooling/heating capacity | L/HR | 200 | - |
Total power input (per hour) | KW | 1.25 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 5~15 | 50-60 |
Water volume to be Cooled/heated | Litres | 1000 | 1000=2000 |
Cooling/heating time for 2000Ltrs | Hrs. | 10 hrs. | - |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | - |
Power tariff (assumed) | Rs. | 7 | - |
Operating cost for Cooling&Heating 2000Ltrs. | Rs | 105 | - |
Max .Output Hot water Temp. | oC | 50-60 | - |
Min. output cool water Temp | oC | 5~15 | - |
Operating temp range(Ambient) | oC | 10â~50 | - |
Material | - | - | Stainless steel |
Therm `Oâ chill foot print | Sqmt | 0.5 | - |
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating/Cooling Unit Model | TCD | 2000 | - |
Water Heating Capacity | L/HR | | 200 |
Water Cooling Capacity | L/HR | 200 | - |
Power in put (per hour) | Kw | 2.5 | - |
No. of units | No | 1 | - |
Total Cooling&heating capacity | L/HR | 400 | - |
Total power input (per hour) | KW | 2.5 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 5~15 | 50-60 |
Water volume to be Cooled&heated | Litres | 2000 | 2000=4000 |
Cooling/heating time for 4000Ltrs | Hrs. | 10 hrs. | - |
Total Energy Consumption(With20% wastage) | Rs/Hr | 21 | - |
Power tariff (assumed) | Rs. | 7 | - |
Operating cost for Cooling&Heating 4000Ltrs. | Rs | 210 | - |
Max .Output Hot water Temp. | oC | 50-60 | - |
Min. output cool water Temp | oC | 5~15 | - |
Operating temp range(Ambient) | oC | 10â~50 | - |
Material | - | - | Stainless steel |
Therm `Oâ chill foot print | Sqmt | 0.5 | - |
Parameter | Unit | Tank 1 | Tank 2 |
Water Heating Capacity | L/HR | | 500 |
Water Cooling Capacity | L/HR | 500 | - |
Power in put (per hour) | Kw | 6.25 | - |
No. of units | No | 1 | - |
Total Cooling&heating capacity | L/HR | 1000 | - |
Total power input (per hour) | KW | 6.25 | - |
Water inlet temp. (Approx) | oC | 30 | 30 |
Water outlet temp(Approx) | oC | 5~15 | 50-60 |
Water volume to be Cooled&heated | Litres | 5000 | 5000=10,000 |
Cooling/heating time for 10,000Ltrs | Hrs. | 10 hrs. | |
Total Energy Consumption(With20% wastage) | Rs/Hr | 52.5 | |
Power tariff (assumed) | Rs. | 7 | |
Operating cost for Cooling&Heating 10,000Ltrs. | Rs | 525 | |
Max .Output Hot water Temp. | oC | 50-60 | |
Min. output cool water Temp | oC | 5~15 | |
Operating temp range(Ambient) | oC | 10â~50 | |
Material | - | - | Stainless steel |
Therm `Oâ chill foot print | Sqmt | 0.5 | - |